ContactContact us My MENMy MEN You are logged off Log in
White Paper: Compact Serial versus VPX The D602 is a 6U CompactPCI COTS computer with onboard functional safety that realizes triple redundancy on a single board to achieve fail-operational, fault-tolerant behavior.

D602 - 6U CompactPCI® PowerPC® Safe Computer

Download the PDF data sheet of D602 Log in to add D602 to My MEN or to view your favorites
Gallery
D602 with PMC slot 2 customized for AFDX PMC (shown with heat sink)

Larger picture of D602 with PMC slot 2 customized for AFDX PMC (shown with heat sink)

Diagram
D602 Diagram

Larger picture of D602 Diagram

Main Features
  • 3x PowerPC® 750 (lockstep mode), 3x 512 MB DDR RAM
  • Fail-operational, fault-tolerant behavior
  • Fail-safe and fail-silent board architecture
  • Clustering of two D602 to raise availability
  • Board management, BITE
  • SEU (radiation) tolerant
  • Certifiable up to SIL 4 (with report from TάV Sόd) and DAL-A
  • Developed according to RTCA DO-254, EN 50129 and IEC 61508
  • EN 50155 compliance
  • Up to -40 to +70°C with qualified components
  • Convection or conduction cooling
Description Open

The D602 is a 6U CompactPCI® COTS computer with onboard functional safety that realizes triple redundancy on a single board to achieve fail-operational, fault-tolerant behavior. The board can also act as a fail-silent subsystem, i.e. it can shut down in case of a fatal fault. Its complex FPGA-based design helps dramatically lower software development costs as it automatically manages the system's triple-redundant processors and memory. The result: The system's redundant architecture is fully taken advantage of by software designed for a standard single-CPU card.

(continued)

Technical Data Open

CPU

3x PowerPC® 750 CL
• Scalable performance
• 1 GHz processor core frequency
• Superscalar
• Classic PowerPC® FPU, MMU
• CPU bus to FPGA: 100-MHz/64-bit

(continued)

Options Open

Mezzanine Slots

PMC slot 2 customized for AFDX® PMC (rear I/O only)

(continued)

Standard Configurations
Article No. CPU Type Clock System RAM Flash FRAM PMC Slots Width Cooling Operating Temperature
02D602-03 3x PPC 750 CL 1 GHz 3x 512 MB 2x 256 MB 1 MB 2 4 HP Convection (air flow 2 m/s) -40..+50°C
Standard D602 Models Open
Related Hardware Open
Certification Packages Open
Miscellaneous Accessories Open
Software
Article No. Description More
VxWorks
Wind RiverThis product is designed to work under VxWorks®. For details regarding supported/unsupported board functions please refer to the corresponding software data sheets.
10D602-60VxWorks® BSP (MEN) for A602 and D602 Download
Details
In addition, this product is supported by Wind River's market-specific OS products VxWorks® 653, VxWorks® DO-178B and VxWorks® 61508. These are certifiable platforms for use in safety and mission-critical systems. For more information and product support please contact MEN or Wind River.
PikeOS
SYSGOThis product is designed to work under PikeOS by SYSGO. The PikeOS BSP has been certified according to DO-178B DAL-B and EN 50128 SIL 4 together with the D602. PikeOS is a real-time operating system for use in safety and mission-critical systems. For more information please contact www.sysgo.com.
Firmware/BIOS
MENMON - firmware/BIOSMENMON is MEN's firmware/BIOS for PowerPC® platforms.
14D602-00MENMON (Firmware) for D602 (object code) Download
Details

For operating systems not mentioned here contact MEN sales.

Documentation
Article No. Description More
02D602-DSD602 Data Sheet (PDF) Download
Compare Chart 6U CompactPCI® cards Download
Compare Chart safe computers from MEN Download
23X602-00SIL 4 railway certification package according to EN 5012x for A602/D602, including:
  • Safety User Manual including the safety-relevant application requirements, a detailed description of the hardware and instructions for appropriate operation.
  • Safety Case describing the concepts for reaching functional safety as well as all safety and quality-relevant processes and measures to meet the SIL 4 requirements.
  • Assessment report and SIL 4 certificate from TάV SάD (German Technical Inspection Agency).
Please contact us to get more information about the certification package and to request a copy of the documents.
For more information on the A602/D602 certification package, see this introductory overview presentation (PDF).
Home Careers Terms & Conditions Legal Notes © 2014 MEN Mikro Elektronik GmbH