PCI Express® and USB interface
Individual reset and power on/off for each PCI Express® Mini Card
•
Via GPIO lines of the PCI Express®/USB controller
Up to 16 additional SIM cards on a special adapter board
USB-SIM socket for SIM emulator
Please note that MEN does not offer SIM cards or mobile telephony contracts!
Front Connections
Up to six Reverse SMA antenna connectors (front panel available as an accessory)
CompactPCI® Bus
Compliance with CompactPCI® Core Specification PICMG 2.0 R3.0
Peripheral slot
32-bit/33-MHz PCI-to-PCI Express® bridge
V(I/O): +3.3V (+5V tolerant)
J2 connector with geographical addressing for distinguishing boards in a system with several boards
Electrical Specifications
Supply voltage/power consumption:
•
+5V (-3%/+5%), depending on plugged card, 1.1 A without PCI Express® Mini Cards
•
+3.3V and 1.5V supply voltage for cards generated onboard
Mechanical Specifications
Dimensions: conforming to CompactPCI® specification for 3U boards
Front panel: 4HP front panel with four SMA connectors available as an accessory
Weight:
•
198 g (with front panel and PCI Express® Mini cards)
•
104 g (without front panel and PCI Express® Mini cards)
Environmental Specifications
Temperature range (operation):
•
-40..+85°C (screened, only carrier, depending on configuration)
•
Airflow: min. 1.0 m/s
Temperature range (storage): -40..+85°C
Relative humidity (operation): max. 95% non-condensing
Relative humidity (storage): max. 95% non-condensing
Altitude: -300 m to + 3,000 m
Shock: 50 m/s², 30 ms (EN 61373)
Vibration (function): 1 m/s², 5 Hz - 150 Hz (EN 61373)
Vibration (lifetime): 7.9 m/s², 5 Hz - 150 Hz (EN 61373)
Conformal coating
MTBF
1,224,236 h @ 40°C according to IEC/TR 62380 (RDF 2000)
Safety
Flammability
•
PCB manufactured with a flammability rating of 94V-0 by UL recognized manufacturers
Electrical Safety
•
Insulation measurement test according to EN 50155 (12.2.9.1) (railway)
•
Voltage withstand test according to EN 50155 (12.2.9.2) (railway)
•
Information technology equipment test according to EN 60950 (information technology equipment)
•
Voltage withstand test according to EN 50124-1 (Annex B) (signal- and telecommunication equipment)
EMC Conformity
EN 55022 (radio and conducted disturbance)
IEC 61000-4-2 (ESD)
IEC 61000-4-3 (electromagnetic field immunity)
IEC 61000-4-4 (burst)
IEC 61000-4-5 (surge)
IEC 61000-4-6 (conducted disturbances)
Software Support
MEN Driver Interface System (MDIS™ for all supported operating systems)