16 bits
Conversion time of D/A converter: <10.5µs
Time between trigger activation and new valid output voltage: <20µs
Output linearity: ±1LSB
Simultaneous updating of all channels
Synchronization with external trigger
Electrically isolated (500V DC isolation)
Voltage Output
Output current: ±6mA max.
Accuracy: ±0.1% (for whole temperature range)
Voltage range: -10V..+10V
Current Output
Accuracy: ±0.5% (for whole temperature range)
Current range: 0..20mA
Max. load resistance: 600 Ohm (or higher with external power supply)
Peripheral Connections
Via front panel on a shielded 25-pin D-Sub receptacle connector
Via carrier board (rear I/O)
M-Module™ Characteristics
A08, D16, INTA, IDENT
Electrical Specifications
Isolation voltage: 500V DC
Supply voltage/power consumption:
•
Through M-Module™-carrier with onboard DC/DC converter: +5V (4.85V..5.25V), 270mA typ., 620mA max.
•
Optional supply current for current transmitters 100 mA typ.
MTBF: 1,012,625h @ 40°C according to IEC/TR 62380 (RDF 2000)
Mechanical Specifications
Dimensions: conforming to M-Module™ Standard
Weight: 90g
Environmental Specifications
Temperature range (operation):
•
-40..+85°C
•
Airflow: min. 10m³/h
Temperature range (storage): -40..+85°C
Relative humidity range (operation): max. 95% non-condensing
Relative humidity range (storage): max. 95% non-condensing
Altitude: -300m to + 3,000m
Shock: 15g/11ms (according to EN60068-2-27)
Bump: 10g/16ms (according to EN60068-2-29)
Vibration (sinusoidal): 2g/10..150Hz (according to EN60068-2-6)
Conformal coating on request
Safety
PCB manufactured with a flammability rating of 94V-0 by UL recognized manufacturers
EMC
Tested according to EN55022 Class A (radio disturbance), EN61000-4-2 (ESD) and EN61000-4-4 (burst)
Software Support
MEN Driver Interface System (MDIS™ for Windows®, Linux, VxWorks®, QNX®, OS-9®)
For more information on supported operating system versions and drivers see Software.