ContactContact us My MENMy MEN You are logged off Log in
Tailored I/O functions realized as IP cores for configuration in onboard FPGAs P506 - Quad CAN Bus Interface PMC

P506 - Quad CAN Bus Interface PMC

Log in to add P506 to My MEN or to view your favorites
Photo
P506 - Quad CAN Bus Interface PMC

Larger picture of P506 - Quad CAN Bus Interface PMC

Diagram
P506 Block Diagram

Larger picture of P506 Block Diagram

Main Features
  • 32-bit/33-MHz PMC
  • Full CAN/Extended CAN
  • 4 independent channels
  • ISO high-speed coupling
  • Up to 1 Mbit/s data transfer rate
  • CANopen master and slave support
  • CAN Layer 2 support
  • Isolation between channels
  • Compliant to ISO 11898-1 and ISO 11898-2
  • -40 to +85°C with qualified components
Description Open

The P506 is a 32-bit/33MHz PMC with four CAN interfaces. They support CAN Protocol Version 2.0A/B, standard and extended data frames, remote frames, 0..8 bytes data length and a programmable data rate of up to 1 Mbit/s.

(continued)

Technical Data Open

CAN Interface

Compliant to ISO 11898-1 and ISO 11898-2

(continued)

FPGA Open

This product offers the possibility to add customized I/O functionality in FPGA.

(continued)

Options Open

CPU

Nios® soft core implementation possible (e.g. for real-time Ethernet)

(continued)

Standard Configurations
Article No. Main FPGA Content Soft Core Memory Signals Cooling Method Operation Temperature
15P506-00 4 CAN bus interfaces No 32 MB RAM, 2 MB Flash Front Convection -40..+85°C
Standard P506 Models
Article No.Description
15P506-00Quad CAN bus interface, 4 CAN cores, front I/O, for convection cooled systems, -40..+85°C with qualified components
Software
Article No.DescriptionMore
OS independent
MDIS™ - MEN Driver Interface SystemTo use MDIS™ low-level drivers, you also need one of the MDIS4™ or MDIS5™ system packages available for Linux, VxWorks®, QNX® or OS-9® (MDIS™ = MEN Driver Interface System).
13Z015-06MDIS5™ low-level driver sources (MEN) for 16Z029_CAN (MSCAN/Layer2)
Requires an MDIS4™/2004 or MDIS5™ system package
Download
Details
13Z016-06MDIS5™ driver (MEN) for 16Z029_CAN (CANopen master)
Requires an MDIS4™/2004 or MDIS5™ system package
Details
13Z061-06MDIS5™ low-level driver sources (MEN) for 16Z061_PWM
Requires an MDIS4™/2004 or MDIS5™ system package
Download
Details
Windows
Windows®This product is designed to work under Windows®. See below for potentially available separate software packages from MEN.
10Y000-78Windows® Embedded Standard 7 BSP for F11S, F19P, F21P, G20, XM1L, XM2, MM1, SC21, F206, F210, F215, F216, G215, P506, P507 and P511Download
Details
13P506-77This Installset includes all free drivers developed by MEN for the supported hardware.Windows® Installset (MEN) for P506
Includes all free drivers developed by MEN for the supported hardware.
Download w/o System Package
Download with System Package
Details
13Z016-70MDIS5™ Windows® driver (MEN) for 16Z029_CAN (CANopen master)
Requires an MDIS4™/2004 or MDIS5™ system package
Download
Details

For operating systems not mentioned here contact MEN sales.

Documentation
Article No.DescriptionMore
15P506-DSP506 Data Sheet (PDF) Download
20P506-00P506 User Manual (PDF) Download
Home Careers Terms & Conditions Legal Notes RSS FeedsRSS Feeds © 2012 MEN Mikro Elektronik GmbH