±1V max. input range, 75 Ohm
Input conditioning via adapter PCB
Trigger
Trigger at signal level, external signal or via software
Rising or falling edge
Trigger at start, middle, end
Clock
Internal or external clock, max. 40MHz
Divider 2n
Buffer
4MB
Random access by the host possible
A/D Conversion
12 bits, 40MSPS
64dB SNR at 3.58MHz
Track/hold
Oversampling technology
Recording
12 ADC bits and 4 external binary inputs
Binary Inputs/Outputs
4 inputs
6 outputs
Peripheral Connections
Via front panel on a shielded combined 15-pin D-Sub receptacle connector
M-Module™ Characteristics
A08, D16, D32, INTA, DMA, IDENT, TRIGI
Electrical Specifications
Isolation voltage: 500V DC
Supply voltage/power consumption:
•
+5V (4.85V..5.25V), 700mA typ. (with sample adapter)
•
+12V (±5%), +50mA
•
-12V (±5%), -40mA
MTBF: tbd. (derived from MIL-HDBK-217F)
Mechanical Specifications
Dimensions: conforming to M-Module™ Standard
Weight: 112g (incl. adapter)
Environmental Specifications
Temperature range (operation):
•
0..+60°C
•
Industrial temperature range on request
•
Airflow: min. 10m³/h
Temperature range (storage): -40..+85°C
Relative humidity range (operation): max. 95% non-condensing
Relative humidity range (storage): max. 95% non-condensing
Altitude: -300m to + 3,000m
Shock: 15g/11ms
Bump: 10g/16ms
Vibration (sinusoidal): 2g/10..150Hz
Conformal coating on request
Safety
PCB manufactured with a flammability rating of 94V-0 by UL recognized manufacturers
EMC
Tested according to EN 55022 (radio disturbance), IEC1000-4-2 (ESD) and IEC1000-4-4 (burst)
Software Support
MEN Driver Interface System (MDIS™ for Windows®, Linux, VxWorks®, QNX®, OS-9®)
For more information on supported operating system versions and drivers see Software.