Complete Profibus DP software on one M-Module™
Local interrupt controller
Hardware watchdog
Slave: SPC 3 Profibus Controller
Up to 12Mbaud data rate
8-bit interface (local)
Complete DP slave protocol
Master: ASPC 2 Profibus Controller
Optional, for M79 as Profibus Master
Up to 12Mbaud data rate
16-bit DMA interface (local)
Complete bus access protocol
Up to 127 active or passive stations
Miscellaneous
1MB shared memory for communication and program
Isolated RS485 Profibus interface
Peripheral Connections
Via front panel on a shielded 9-pin D-Sub receptacle connector
M-Module™ Characteristics
A08, D16, INTA, IDENT
Electrical Specifications
Electrical isolation: 500V DC
•
500V DC between isolated side and digital side
•
Voltage between the connector shield and isolated ground is limited to 180V using a varistor; AC coupling between connector shield and isolated ground through 47nF capacitor
Supply voltage/power consumption:
•
+5V (4.85V..5.25V), 287mA
MTBF: 860,000h @ 40°C (derived from MIL-HDBK-217F)
Mechanical Specifications
Dimensions: conforming to M-Module™ Standard
Weight: 53g
Environmental Specifications
Temperature range (operation):
•
0..+60°C or -40..+85°C
•
Airflow: min. 10m³/h
Temperature range (storage): -40..+85°C
Relative humidity (operation): max. 95% non-condensing
Relative humidity (storage): max. 95% non-condensing
Altitude: -300m to + 3,000m
Shock: 15g/11ms
Bump: 10g/16ms
Vibration (sinusoidal): 2g/10..150Hz
Conformal coating on request
Safety
PCB manufactured with a flammability rating of 94V-0 by UL recognized manufacturers
EMC
Tested according to EN 55022 (radio disturbance), IEC1000-4-2 (ESD) and IEC1000-4-4 (burst)
Software Support
Softing protocol portation (ISO/OSI protocol layer 2/DP)
MEN Driver Interface System (MDIS™ for Windows®, Linux, VxWorks®, QNX®, OS-9®)
For more information on supported operating system versions and drivers see Software.