Individual use of each channel as input or output
Individual edge-triggered interrupts
Input/output load on ground
High-side output switches
High output current
•
Max. 1.9A per channel
•
Max. 16A per unit
Over-current and over-temperature protection
Output Characteristics
Output voltage range: 12V..32V
Output current log. 0: max. 10mA
Output current log. 1: max. 1.9A
Switching time for output change: < 200µs
Isolation voltage (optocoupler): 500V DC
Input Characteristics
Input voltage min.: 0V
Input voltage max. external supply voltage (12..32V)
Voltage level log. 0: 0V..6V or open
Voltage level log. 1: 12V..32V
Input current log. 1: 2.03mA @ 24V
Switching threshold: 9.2V @ 0.78mA typ.
Switching time for input change: min. 33µs, max. 44µs
Excess voltage protection: max. +47V
Peripheral Connections
Via front panel on four shielded 44-pin HD-Sub receptacle connectors
VMEbus
Only one slot required on the VMEbus
A24/A16/D16/D08(EO) slave
D08(O) interrupter
Electrical Specifications
Isolation voltage
•
500V DC between isolated side and digital side
•
180V DC between the channels
•
Voltage between the connector shield and isolated ground is limited to 180V using a varistor; AC coupling between connector shield and isolated ground through 47nF capacitor
Supply voltage/power consumption:
•
+5V (4.85V..5.25V), 106mA
•
+3.3V (3.0V..3.6V), 27mA
•
+24V (external supply voltage 12..32V), 78mA (total for all units)
MTBF: 98,000h @ 50°C (derived from MIL-HDBK-217F)
Mechanical Specifications
Dimensions: standard double Eurocard, 233.3mm x 160mm
Weight: 280g
Environmental Specifications
Temperature range (operation):
•
0..+60°C or -40..+85°C
•
Airflow: min. 10m³/h
Temperature range (storage): -40..+85°C
Relative humidity range (operation): max. 95% without condensation
Relative humidity range (storage): max. 95% without condensation
Altitude: -300m to + 3,000m
Shock: 15g/11ms
Bump: 10g/16ms
Vibration (sinusoidal): 2g/10..150Hz
Conformal coating on request
Safety
PCB manufactured with a flammability rating of 94V-0 by UL recognized manufacturers
EMC
Tested according to EN 55022 (radio disturbance), IEC1000-4-2 (ESD) and IEC1000-4-4 (burst)
Software Support
MEN Driver Interface System (MDIS™ for Windows®, Linux, VxWorks®, QNX®, OS-9®)
For more information on supported operating system versions and drivers see Software.