Intelligent Well System Control

Standard Components Used in this Example

This control platform for intelligent well systems is realized as a pre-integrated and pre-validated 3-slot 3U 24HP CompactPCI system with its own rugged power supply unit, a PU2. The system's core is an F14 Intel Pentium M SBC (1 GHz, 512 MB of RAM) running Windows XP Professional. It offers 1 Gigabit Ethernet and 1 Fast Ethernet interface and it is equipped with an F600 side card and an F206 peripheral card, each adding two UARTs. The F600 also serves as a hard-disk drive carrier for an 80GB HDD. The entire system is designed for an operating temperature from -40 to +85°C.

Standard Components Used in this Example

F14 - Intel Pentium M CPU Board

Equipped with the high-performance Intel 2-GHz Pentium M down to the 1-GHz ultra low voltage Celeron M processor, the F14 is a 4 HP/3U CompactPCI board, designed for embedded systems with high computing/graphics performance and low power consumption.


F206 - Octal UART for RS232, RS422, RS485

The F206 is a universal octal UART based on 3U CompactPCI and uses small adapter to implement the physical layer for each channel as RS-232, RS-422, RS-485.


F600 - Side Card for SATA/Legacy I/O

The F600 is a 4HP legacy I/O extension card for 3U Intel based CompactPCI single-board computers. It can be used in combination with the F14 and compatible CPU boards.


PU2 - Power Supply Unit, 24 VDC, 35 W

The PU2 3U 8HP power supply unit is a plug-in device for 19" systems (e.g. VMEbus, CompactPCI) and is especially designed for computer systems in public transport vehicles, being fully compliant with EN 50155.


Contact Request! Use this form to get the fastest possible reply.
Please make sure to fill out the complete form, so we can provide quick and specific support.
Your request will be sent to our sales team.

Your information will not be shared!

* required fields

Your Request

Your Contact Data

Please type in the letters and/or numbers that you see in the image on the left (case-sensitive).