SA24M - IBIS Master

SA-Adapter

The SA24M is an IBIS master interface adapter with one IBIS master interface.

Download data sheet

  • SA24M Product ImageSA24M - IBIS Master SA-Adapter
  • SA24M Product ImageSA24M - IBIS Master SA-Adapter
  • SA24M Product Image
  • SA24M Product Image

Main Features

  • 1 channel master
  • Over-current and short-cut protection
  • Optical isolation
  • -40 to +85°C screened
SA24M Product Image

Technical Data

Interfaces
  • IBIS master on front connector
    • External 24V power supply on front connector for IBIS signal level
    • Standard IBIS data rate (1200 bit/s) up to standard UART data rate (up to 9600 bit/s)
  • Serial TTL Interface on 10-pin SA-Adapter connector
Installation
  • As a piggy-back board directly on a carrier board
  • Via ribbon cable
Peripheral Connections
Via front panel on a shielded 9-pin D-Sub receptacle connector
Electrical Specifications
  • Isolation voltage:
    • 750V DC or 500V AC between isolated side and digital side
  • Supply voltage/power consumption:
    • Digital side +5V (-3%/+5%), 10 mA typ. (25 mA max.)
    • Isolated side +24V (-30%/+25%), 10mA typ. (110 mA max., when loopback on pin 1/2)
  • MTBF: tbd @ 40°C according to IEC/TR 62380 (RDF 2000)
Mechanical Specifications
  • Dimensions: 32mm x 42mm
  • Weight:
    • 18g (Master)
Environmental Specifications
  • Temperature range (operation):
    • -40..+85°C (qualified)
  • Temperature range (storage): -40..+85°C
  • Relative humidity (operation): max. 95% non-condensing
  • Relative humidity (storage): max. 95% non-condensing
  • Altitude: -300m to + 3,000m
  • Shock:
    • 50 m/s², 30 ms (EN 61373)
    • 15 g, 11 ms (EN 60068-2-27)
  • Vibration (function): 2.02 m/s², 5 Hz to 150 Hz (EN 61373)
  • Vibration (lifetime): 11.44 m/s², 5 Hz to 150 Hz (EN 61373)
  • Conformal coating
Safety
Flammability (PCBs)
  • UL 94 V-0
EMC
  • EN 50121-3-2 (conducted disturbance)
  • IEC 61000-4-4 (burst)
  • IEC 61000-4-6 (conducted disturbances)

Ordering Information

Standard SA24M Models
08SA24M00

IBIS master SA-Adapter, conformal coating, -40...+85°C screened

08SA24M01

IBIS master SA-Adapter, -40...+85°C screened

Contact Request! Use this form to get the fastest possible reply.
Please make sure to fill out the complete form, so we can provide quick and specific support.
Your request will be sent to our sales team.

Your information will not be shared!

* required fields

Your Request

Your Contact Data

Please type in the letters and/or numbers that you see in the image on the left (case-sensitive).